Samsung heat pump error codes and flashing lights

Samsung puts its fault codes on the indoor display, often split into two halves. Here's how to read them and what they point to, for homes across South Auckland.

The work
Fault-finding and repairs on heat pumps and air con, plus servicing
Phil
An electrician by trade, fixing heat pumps since 2012
Brands
Mitsubishi, Fujitsu, Panasonic, Daikin and the other main brands
Where
Manukau, Papatoetoe and Māngere down to Papakura, Drury and Beachlands
SAMSUNGE121POWER
WHAT TO TELL PHILSOUTH AUCKLAND

Samsung · code E121 · send it to Phil

Brand
Samsung
Code
E121
Model
off the side sticker

When your Samsung shows a fault

On a Samsung in Manukau or South Auckland, a fault blinks up as a code on the indoor display, with the indicator lamp blinking too. Three-digit codes come in two halves shown one after the other, so E1 then 22 is E122.

Newer Samsungs use C where older ones use E, and the numbers mean the same thing, so C101 is the same fault as E101. Most of these codes point to a sensor, a board, a fan motor or the power supply, and Phil's an electrician by trade.

Phil starts from the code and the model. Send him both halves of the code and the model, or give us a call.

Reading a Samsung display code

Watch the display for a few seconds. E1 followed by 22 is one code, E122, so write down both halves before you turn anything off.

Older or simpler Samsungs show a short code, like E1 or E5, that doesn't flip to more digits. Those have their own meanings, listed at the bottom.

Some newer models keep their last few codes in memory, and Phil can bring them up when he's there.

The model number

It’s on a sticker on the indoor unit. A photo of it is all Phil needs.

Send it to Phil

The code or the light count, the model and what the unit is doing. Ring 0800 925 417 or use the form below.

Samsung codes and what they point to

These are the codes on Samsung's current models. Send Phil the model with the code and he'll confirm what it means on your unit.

E1 and C1 codes: indoor unit and the link

Shown as E1 or C1, then the last two digits.

  • E101 / C101Electrical

    The indoor and outdoor units can't talk to each other. It comes up when they haven't made contact within about a minute.

    Points to no power to the outdoor unit, the link wiring, or either board, and now and then a one-off glitch

  • E102 / C102Electrical

    Another fault on the link between the indoor and outdoor units, listed alongside E101.

    Points to the link wiring, power to the outdoor unit, or either board

  • E121 / C121Electrical

    The room temperature sensor on the indoor unit has failed, and the unit may not turn on at all.

    Points to the room air sensor or the indoor board

  • E122 / C122Electrical

    The temperature sensor on the indoor unit's coil is faulty.

    Points to the indoor coil sensor or the indoor board

  • E154 / C154Electrical

    The indoor fan isn't getting up to speed. If it only happens now and then, a surge in the mains voltage can trip the fan motor's protection.

    Points to the indoor fan motor, its capacitor on older models, the indoor board, or high mains voltage

  • E162 / C162Electrical

    The memory chip on the indoor board has a fault.

    Points to the indoor board

  • E163 / C163Electrical

    The settings stored on the indoor board are wrong or have been lost. It tends to show after a board change.

    Points to the option settings stored on the indoor board

  • E186 / C186Electrical

    A feedback signal on the indoor board has failed. Samsung doesn't go into more detail than that.

    Points to the indoor board or a module plugged into it

E2 and C2 codes: outdoor link and sensors

Shown as E2 or C2, then the last two digits.

  • E201 / C201Electrical

    On a multi-room system, the number of indoor units the outdoor unit can find doesn't match how it's been set up.

    Points to the setting dial on the outdoor unit, the link wiring, or the power wiring

  • E202 / C202Electrical

    The indoor and outdoor units have been out of contact for more than a minute.

    Points to the link wiring, power to the outdoor unit, or either board

  • E203 / C203Electrical

    The two boards in the outdoor unit, main and inverter, have lost contact with each other.

    Points to either outdoor board, or the lead joining them

  • E221 / C221Electrical

    The sensor that reads the outside air temperature has failed.

    Points to the outdoor air sensor or the outdoor board

  • E231 / C231Electrical

    The temperature sensor on the outdoor coil has packed up.

    Points to the outdoor coil sensor or the outdoor board

  • E237 / C237Electrical

    A second outdoor temperature sensor code, grouped with E221.

    Points to an outdoor sensor or the outdoor board

  • E251 / C251Electrical

    The sensor on the compressor's outlet pipe has failed.

    Points to the discharge pipe sensor or the outdoor board

E4 and C4 codes: outdoor unit and compressor

Shown as E4 or C4, then the last two digits.

  • E416 / C416

    The pipe coming off the compressor is running too hot.

    Points to low gas or a blockage, poor airflow at the outdoor unit, or the discharge sensor

  • E440 / E441

    The unit won't run in the mode you've picked because it's outside its working range, mainly on outdoor temperature.

    Points to outdoor temperature too high or too low for heating or cooling

  • E458 / C458Electrical

    The outdoor fan isn't holding the speed it's asked for.

    Points to the outdoor fan motor, something in the way of the fan, or the fan drive on the outdoor board

  • E461 / C461Electrical

    The compressor was asked to start and didn't.

    Points to the compressor, its wiring, or the inverter board

  • E462 / C462Electrical

    The current coming in, or in the power-factor circuit, went too high and the unit tripped itself.

    Points to the inverter board in the outdoor unit, too much load on the compressor, or the mains

  • E464 / C464Electrical

    The compressor's power module on the inverter board has carried too much current.

    Points to the power module on the inverter board, the compressor, or its wiring

  • E465 / C465Electrical

    The compressor hit its voltage or current limit and the unit stopped to protect it.

    Points to load on the compressor, the inverter board, or gas conditions

  • E466 / C466Electrical

    The DC voltage inside the inverter is out of range, either high or low.

    Points to the mains supply or the outdoor inverter board

  • E467 / C467Electrical

    The compressor isn't turning the way it should.

    Points to the compressor, its leads, or the inverter board

  • E468 / C468Electrical

    The outdoor board's current sensor is faulty.

    Points to the outdoor inverter board

  • E469 / C469Electrical

    The outdoor board can't measure its DC voltage, as that sensor is faulty.

    Points to the outdoor inverter board

  • E470 / C470Electrical

    The memory chip on the outdoor board has a fault.

    Points to the outdoor board

  • E471 / C471Electrical

    An over-temperature protection fault on the outdoor board.

    Points to the outdoor board

  • E472 / C472Electrical

    The outdoor board can't pick up the timing signal it takes from the mains supply.

    Points to the quality of the supply, or the outdoor board

  • E474 / C474Electrical

    The inverter heat sink's temperature sensor is faulty.

    Points to that sensor, or the inverter board in the outdoor unit

  • E483 / C483Electrical

    The DC voltage circuit in the inverter has seen too much voltage.

    Points to the outdoor inverter board, or spikes on the supply

  • E484 / C484Electrical

    The power-factor circuit in the outdoor unit is overloaded.

    Points to the outdoor inverter board, or an overload

  • E485 / C485Electrical

    The sensor that measures the current coming in has failed.

    Points to the outdoor board, where that sensor sits

E5, C5 and E6 codes: heat, gas, setup and wired controllers

  • E500 / C500Electrical

    The heat sink on the inverter board is too hot.

    Points to airflow at the outdoor unit, or the inverter board

  • E554 / C554

    The system has picked up a gas leak.

    Points to gas escaping from the pipework, or a low charge

  • E556 / C556

    The indoor and outdoor units don't match in size.

    Points to a mismatched indoor and outdoor pair, or how they've been set up

  • E604 / C604Electrical

    The wired controller on the wall has lost contact with the indoor unit.

    Points to the controller type, its wiring, or the power to the controller

Older Samsungs with two-character codes

A short code that stays put and doesn't flip to more digits.

  • E1Electrical

    The room temperature sensor has shorted or failed, which stops the unit turning on.

    Points to the room air sensor

  • E5Electrical

    The sensor on the indoor coil has gone open or short.

    Points to the indoor coil sensor

  • E6Electrical

    The sensor on the outdoor coil has gone open or short.

    Points to the outdoor coil sensor

  • E7Electrical

    The heater temperature sensor has gone open or short.

    Points to the heater sensor

  • EC

    Either the system is low on gas or one of the sensors isn't working.

    Points to a gas leak, or a faulty sensor

Samsung display messages that aren't faults

  • dF

    Defrost in heating. The indoor fan stops for a while and you might see steam off the outdoor unit. It takes about 5 to 12 minutes.

  • CF

    The filter reminder. It comes up on a timer, and you clear it from the remote once the filters are done.

  • CI or CL

    Auto Clean drying the inside of the unit after you switch off, so the fan keeps going. You can turn it off on the remote.

  • Lamps blinking during a self-test

    Some models run a self-test that takes 7 to 13 minutes, with a counter on the display. The lamps can blink and the remote won't respond until it's done.

Heat Pump Doctors logo

Heat Pump Doctors, in Manukau since 2012

South Auckland Heat Pump Services is Phil of Heat Pump Doctors. He’s been fixing heat pumps and air con across South Auckland since 2012, and he’s an electrician by trade.

We find the fault first, then tell you what it is and what it’ll take before any repair goes ahead.

More about us

Samsung code questions

Something else? Ring 0800 925 417 or put it in the form.

My Samsung shows C101 but I can only find E101. Are they the same?

Yes. Newer Samsungs use C where older ones use E, and the numbers mean the same fault.

Why does my Samsung flash two different codes?

It's one code shown in two halves. E1 then 22 is E122, so note down both and send them to Phil together.

My Samsung showed C154 once, then carried on. Does it need a look?

A one-off can come from a surge in the mains voltage tripping the fan motor's protection. If it comes straight back after a restart, it points to the fan motor or the board, so send Phil the code and the model.

Send Phil your Samsung code

The brand is already picked. Add the code or the light count, the model and your suburb, and Phil calls you back.

Call 0800 925 417

What helps Phil most

  • The brand and the model number, off the sticker on the side
  • Which light is flashing and how many times, or the code
  • What the unit is doing, and since when
  • A photo of the lights or the sticker