Daikin heat pump error codes and flashing lights
Look up the code your Daikin remote shows and see the part it points to, with repairs across Manukau and South Auckland.
- The work
- Fault-finding and repairs on heat pumps and air con, plus servicing
- Phil
- An electrician by trade, fixing heat pumps since 2012
- Brands
- Mitsubishi, Fujitsu, Panasonic, Daikin and the other main brands
- Where
- Manukau, Papatoetoe and Māngere down to Papakura, Drury and Beachlands
Daikin · light flashing · send it to Phil
- Brand
- Daikin
- Lights
- which light, how many flashes
- Model
- off the side sticker
When your Daikin shows a fault
Your Daikin has stopped and the OPERATION lamp is blinking. It's found a fault and saved a code, and the remote can tell you which one. We fix Daikin units across Manukau and South Auckland, and Phil starts from that code.
Most Daikin codes are electrical, from sensors and fan motors to boards and the supply voltage, and that's Phil's trade.
Write the code down, grab the model off the label and give Phil a call. If it keeps tripping the power, turn it off at the switchboard first.
Getting the code out of a Daikin
A blinking OPERATION lamp means a fault. On the Alira X it's the first lamp in the row at the lower right of the unit, and on the Cora and Lite it's in the column on the right of the display.
On a Zena the round lamp flashes instead. Ducted units with a wired controller show "Error: Push Menu button", and pressing Menu brings up the code.
On wall units, the remote reads the stored code with the Cancel button.
- Hold Cancel for about 5 seconds, until 00 blinks on the remote.
- Point the remote at the unit and press Cancel again and again. Each press shows a new code, and a short beep or a double beep means that's not the one.
- A long beep means the code on the screen is the fault. Write it down.
- Hold Cancel for 5 seconds to finish, or leave it and it stops by itself after a minute.
The model number
The model name is on a label at the lower right of the indoor unit's front edge, near the display.
Send it to Phil
The code or the light count, the model and what the unit is doing. Ring 0800 925 417 or use the form below.
Daikin codes and what they point to
Each code shows what's gone wrong and the part Phil looks at first. The last two groups cover other Daikin models, so send the model with the code and he'll confirm it for your unit.
Wall units (Alira X, Cora, Lite)
Read with the Cancel button on the remote.
00
No fault stored. It's where the list starts when you step through with Cancel.
Points to nothing, it's the starting point
A1Electrical
The indoor circuit board has a fault.
Points to the indoor main board or its plugs
A5
The indoor coil has iced up in cooling or got too hot in heating, and the unit has stopped to protect itself.
Points to blocked airflow, dirty filters or coil, or the coil sensor
Safe to try make sure the filters are clean and nothing's blocking the vents inside or out, then turn it off and on at the switchboard.
A6Electrical
The indoor fan motor has a fault.
Points to the indoor fan motor, something jamming the fan, or the indoor board
C4Electrical
The sensor on the indoor coil has failed.
Points to the indoor coil sensor or its plug
C9Electrical
The sensor reading the room air has failed.
Points to the room air sensor or the indoor board
CCElectrical
The humidity sensor has failed, on models that have one.
Points to the humidity sensor
E1Electrical
The outdoor circuit board has a fault.
Points to the outdoor main board, or noise on the supply
E5
The compressor's overload protection has tripped.
Points to a valve not fully open, low gas, the outdoor fan, or the compressor or its wiring
E6
The compressor tried to start and couldn't turn.
Points to the compressor or its wiring, a closed valve or the outdoor board
E7Electrical
The outdoor fan motor has a fault.
Points to the outdoor fan motor, debris in the fan, or the outdoor board
E8Electrical
Too much current is coming into the outdoor unit.
Points to the compressor or its wiring, or the outdoor board
EA
The unit can't change over between cooling and heating.
Points to the 4-way valve or its coil, a sensor or the outdoor board
F3
The pipe leaving the compressor is running too hot.
Points to the gas charge, a closed valve, the expansion valve or a sensor
F6
Pressure got too high while cooling.
Points to a blocked outdoor coil, poor airflow at the outdoor unit or the outdoor fan
Safe to try with the power off at the switchboard, make sure nothing is blocking the air in or out of the outdoor unit.
F8
The inside of the compressor got too hot and it stopped.
Points to too much gas, air in the system, a blockage or the discharge sensor
H0Electrical
A sensor in the compressor's control system has failed.
Points to the sensing circuit on the outdoor board, or the compressor wiring
H6Electrical
The board couldn't track the compressor's position, so it stopped it.
Points to the compressor or its wiring, the outdoor board or the supply voltage
H8Electrical
The DC current sensor has a fault.
Points to the outdoor board, or the compressor or its wiring
H9Electrical
The outside air sensor has failed. Daikin's own list calls it the suction air sensor.
Points to the outdoor air sensor or the outdoor board
J3Electrical
The sensor on the discharge pipe has failed.
Points to the discharge pipe sensor or the outdoor board
J6Electrical
The outdoor coil sensor has failed.
Points to the outdoor coil sensor or the outdoor board
J8Electrical
The liquid pipe sensor has failed. This one is listed for the Alira X.
Points to the liquid pipe sensor
L3Electrical
The electrical parts in the outdoor switch box are overheating.
Points to the outdoor fan motor, the fin sensor or the outdoor board
L4Electrical
The inverter's heat sink is running too hot.
Points to the outdoor fan, a dirty outdoor coil or the outdoor board
L5Electrical
The inverter is sending too much current to the compressor.
Points to the compressor or its wiring, or the power module on the outdoor board
P4Electrical
The heat sink sensor on the outdoor board has failed.
Points to the fin sensor on the outdoor board
U0
The unit has picked up a shortage of refrigerant.
Points to a gas leak, a closed valve, a blockage or a sensor
U2Electrical
The supply voltage has dropped too low or gone too high.
Points to the mains supply or the voltage circuit on the outdoor board
U4Electrical
The indoor and outdoor units have stopped talking to each other.
Points to the cable between the units, a control board or the supply
UA
The indoor and outdoor units aren't a valid pairing.
Points to the indoor and outdoor combination, or the wiring between them
Zena and other Daikin wall models
AHElectrical
The streamer air cleaner has a fault, and the unit keeps running without it.
Points to the streamer unit
C5Electrical
The second indoor coil sensor has failed.
Points to indoor coil sensor 2 or the indoor board
C7Electrical
The moving front panel won't open or close properly.
Points to the front panel drive or its limit switch
Safe to try if something's caught in the front panel, clear it and restart with the remote.
E4
Pressure on the low side has dropped too far.
Points to the refrigerant circuit
E9Electrical
The electronic expansion valve has a fault.
Points to the expansion valve
H7Electrical
The outdoor fan motor has overloaded or drawn too much current, or its sensor has failed.
Points to the outdoor fan motor
J1Electrical
The pressure sensor has failed.
Points to the pressure sensor
J5Electrical
The suction pipe sensor has failed.
Points to the suction pipe sensor
J7Electrical
The sub-cooling coil sensor has failed.
Points to the sub-cooling sensor
J9Electrical
The gas pipe sensor has failed.
Points to the gas pipe sensor
L1Electrical
The inverter board has a fault.
Points to the inverter board
L8Electrical
The compressor is drawing too much current.
Points to the compressor or its drive
L9Electrical
Overcurrent protection has stepped in as the compressor starts.
Points to the compressor start circuit
LCElectrical
The outdoor control board and the inverter board have stopped talking.
Points to the outdoor control and inverter boards
P1Electrical
A phase is missing, or the supply voltage is out of balance.
Points to the power supply
PJElectrical
The unit's capacity setting is wrong.
Points to the capacity setting on the board
U7Electrical
Inside the outdoor unit, the main board and the power module have lost contact.
Points to the outdoor board
UF
The pipes and wiring between the units don't match up, or there's not enough refrigerant.
Points to the pipe and cable connections, or low gas
Ducted units with a wired controller
Press Menu on the controller to see the code and the unit number.
A3
The water level in the condensate drain has risen too high.
Points to the drain pump, the drain pipe or a blockage
A8Electrical
The power feeding the indoor fan board is out of range.
Points to the indoor fan board or its supply
AF
The drain float has tripped.
Points to the drain float or the drain line
CJElectrical
The temperature sensor inside the wired controller has failed.
Points to the wired controller's sensor
U5Electrical
The indoor unit and the wired controller can't talk, for example when two controllers are both set as main.
Points to the controller wiring or settings, or the indoor board
U8Electrical
The main and second wired controllers can't talk to each other.
Points to the controller settings or wiring
When a Daikin looks broken but isn't
Defrost
Heating stops for about 4 to 12 minutes with a whistling or running-water sound, and the outdoor unit steams. Warm air comes back once it's done.
Stops with the lamp still lit
That's the unit protecting itself from a big swing in the supply voltage. It restarts by itself in about 3 minutes.
Running after you turn it off
After cooling or dry mode, MOLD PROOF keeps the unit running for up to an hour to dry itself out.
Dark display
The display brightness can be set to off, so the lamps can be dark while the unit's running.

Heat Pump Doctors, in Manukau since 2012
South Auckland Heat Pump Services is Phil of Heat Pump Doctors. He’s been fixing heat pumps and air con across South Auckland since 2012, and he’s an electrician by trade.
We find the fault first, then tell you what it is and what it’ll take before any repair goes ahead.
Other brands’ codes
- Mitsubishi ElectricBlink counts on the operation lamp, and P, E and U codes
- FujitsuOperation and Timer flashes that make a two-digit code
- PanasonicH and F codes behind a blinking timer light
- HitachiTimer lamp blink counts
- ToshibaWhich lamps flash together, and how fast
- LGCH codes on the display or as lamp blinks
- SamsungE and C codes on the indoor display
- HaierE and F codes on the two-digit display
- GreeE, F, H and L codes on the temperature display
- CarrierE, P and F codes in the display window
Daikin code questions
Something else? Ring 0800 925 417 or put it in the form.
How do I find the code on my Daikin remote?
Hold Cancel for 5 seconds until 00 blinks, then keep pressing Cancel. Whatever code is showing when the unit gives a long beep is the fault.
My Daikin stopped but the light didn't blink. Is it broken?
If the OPERATION lamp stays lit, the unit has shut down to protect itself from a swing in the supply voltage. It starts again on its own in about 3 minutes.
What does U4 mean on a Daikin?
U4 means the indoor and outdoor units have lost contact, which comes down to the cable between them, a board or the supply. Turn it off at the switchboard and ring Phil with the model.
Send Phil your Daikin code
The brand is already picked. Add the code or the light count, the model and your suburb, and Phil calls you back.
What helps Phil most
- The brand and the model number, off the sticker on the side
- Which light is flashing and how many times, or the code
- What the unit is doing, and since when
- A photo of the lights or the sticker