When your Daikin shows a fault

Your Daikin has stopped and the OPERATION lamp is blinking. It's found a fault and saved a code, and the remote can tell you which one. We fix Daikin units across Manukau and South Auckland, and Phil starts from that code.

Most Daikin codes are electrical, from sensors and fan motors to boards and the supply voltage, and that's Phil's trade.

Write the code down, grab the model off the label and give Phil a call. If it keeps tripping the power, turn it off at the switchboard first.

Getting the code out of a Daikin

A blinking OPERATION lamp means a fault. On the Alira X it's the first lamp in the row at the lower right of the unit, and on the Cora and Lite it's in the column on the right of the display.

On a Zena the round lamp flashes instead. Ducted units with a wired controller show "Error: Push Menu button", and pressing Menu brings up the code.

On wall units, the remote reads the stored code with the Cancel button.

  1. Hold Cancel for about 5 seconds, until 00 blinks on the remote.
  2. Point the remote at the unit and press Cancel again and again. Each press shows a new code, and a short beep or a double beep means that's not the one.
  3. A long beep means the code on the screen is the fault. Write it down.
  4. Hold Cancel for 5 seconds to finish, or leave it and it stops by itself after a minute.

The model number

The model name is on a label at the lower right of the indoor unit's front edge, near the display.

Send it to Phil

The code or the light count, the model and what the unit is doing. Ring 0800 925 417 or use the form below.

Daikin codes and what they point to

Each code shows what's gone wrong and the part Phil looks at first. The last two groups cover other Daikin models, so send the model with the code and he'll confirm it for your unit.

Wall units (Alira X, Cora, Lite)

Read with the Cancel button on the remote.

  • 00

    No fault stored. It's where the list starts when you step through with Cancel.

    Points to nothing, it's the starting point

  • A1Electrical

    The indoor circuit board has a fault.

    Points to the indoor main board or its plugs

  • A5

    The indoor coil has iced up in cooling or got too hot in heating, and the unit has stopped to protect itself.

    Points to blocked airflow, dirty filters or coil, or the coil sensor

    Safe to try make sure the filters are clean and nothing's blocking the vents inside or out, then turn it off and on at the switchboard.

  • A6Electrical

    The indoor fan motor has a fault.

    Points to the indoor fan motor, something jamming the fan, or the indoor board

  • C4Electrical

    The sensor on the indoor coil has failed.

    Points to the indoor coil sensor or its plug

  • C9Electrical

    The sensor reading the room air has failed.

    Points to the room air sensor or the indoor board

  • CCElectrical

    The humidity sensor has failed, on models that have one.

    Points to the humidity sensor

  • E1Electrical

    The outdoor circuit board has a fault.

    Points to the outdoor main board, or noise on the supply

  • E5

    The compressor's overload protection has tripped.

    Points to a valve not fully open, low gas, the outdoor fan, or the compressor or its wiring

  • E6

    The compressor tried to start and couldn't turn.

    Points to the compressor or its wiring, a closed valve or the outdoor board

  • E7Electrical

    The outdoor fan motor has a fault.

    Points to the outdoor fan motor, debris in the fan, or the outdoor board

  • E8Electrical

    Too much current is coming into the outdoor unit.

    Points to the compressor or its wiring, or the outdoor board

  • EA

    The unit can't change over between cooling and heating.

    Points to the 4-way valve or its coil, a sensor or the outdoor board

  • F3

    The pipe leaving the compressor is running too hot.

    Points to the gas charge, a closed valve, the expansion valve or a sensor

  • F6

    Pressure got too high while cooling.

    Points to a blocked outdoor coil, poor airflow at the outdoor unit or the outdoor fan

    Safe to try with the power off at the switchboard, make sure nothing is blocking the air in or out of the outdoor unit.

  • F8

    The inside of the compressor got too hot and it stopped.

    Points to too much gas, air in the system, a blockage or the discharge sensor

  • H0Electrical

    A sensor in the compressor's control system has failed.

    Points to the sensing circuit on the outdoor board, or the compressor wiring

  • H6Electrical

    The board couldn't track the compressor's position, so it stopped it.

    Points to the compressor or its wiring, the outdoor board or the supply voltage

  • H8Electrical

    The DC current sensor has a fault.

    Points to the outdoor board, or the compressor or its wiring

  • H9Electrical

    The outside air sensor has failed. Daikin's own list calls it the suction air sensor.

    Points to the outdoor air sensor or the outdoor board

  • J3Electrical

    The sensor on the discharge pipe has failed.

    Points to the discharge pipe sensor or the outdoor board

  • J6Electrical

    The outdoor coil sensor has failed.

    Points to the outdoor coil sensor or the outdoor board

  • J8Electrical

    The liquid pipe sensor has failed. This one is listed for the Alira X.

    Points to the liquid pipe sensor

  • L3Electrical

    The electrical parts in the outdoor switch box are overheating.

    Points to the outdoor fan motor, the fin sensor or the outdoor board

  • L4Electrical

    The inverter's heat sink is running too hot.

    Points to the outdoor fan, a dirty outdoor coil or the outdoor board

  • L5Electrical

    The inverter is sending too much current to the compressor.

    Points to the compressor or its wiring, or the power module on the outdoor board

  • P4Electrical

    The heat sink sensor on the outdoor board has failed.

    Points to the fin sensor on the outdoor board

  • U0

    The unit has picked up a shortage of refrigerant.

    Points to a gas leak, a closed valve, a blockage or a sensor

  • U2Electrical

    The supply voltage has dropped too low or gone too high.

    Points to the mains supply or the voltage circuit on the outdoor board

  • U4Electrical

    The indoor and outdoor units have stopped talking to each other.

    Points to the cable between the units, a control board or the supply

  • UA

    The indoor and outdoor units aren't a valid pairing.

    Points to the indoor and outdoor combination, or the wiring between them

Zena and other Daikin wall models

  • AHElectrical

    The streamer air cleaner has a fault, and the unit keeps running without it.

    Points to the streamer unit

  • C5Electrical

    The second indoor coil sensor has failed.

    Points to indoor coil sensor 2 or the indoor board

  • C7Electrical

    The moving front panel won't open or close properly.

    Points to the front panel drive or its limit switch

    Safe to try if something's caught in the front panel, clear it and restart with the remote.

  • E4

    Pressure on the low side has dropped too far.

    Points to the refrigerant circuit

  • E9Electrical

    The electronic expansion valve has a fault.

    Points to the expansion valve

  • H7Electrical

    The outdoor fan motor has overloaded or drawn too much current, or its sensor has failed.

    Points to the outdoor fan motor

  • J1Electrical

    The pressure sensor has failed.

    Points to the pressure sensor

  • J5Electrical

    The suction pipe sensor has failed.

    Points to the suction pipe sensor

  • J7Electrical

    The sub-cooling coil sensor has failed.

    Points to the sub-cooling sensor

  • J9Electrical

    The gas pipe sensor has failed.

    Points to the gas pipe sensor

  • L1Electrical

    The inverter board has a fault.

    Points to the inverter board

  • L8Electrical

    The compressor is drawing too much current.

    Points to the compressor or its drive

  • L9Electrical

    Overcurrent protection has stepped in as the compressor starts.

    Points to the compressor start circuit

  • LCElectrical

    The outdoor control board and the inverter board have stopped talking.

    Points to the outdoor control and inverter boards

  • P1Electrical

    A phase is missing, or the supply voltage is out of balance.

    Points to the power supply

  • PJElectrical

    The unit's capacity setting is wrong.

    Points to the capacity setting on the board

  • U7Electrical

    Inside the outdoor unit, the main board and the power module have lost contact.

    Points to the outdoor board

  • UF

    The pipes and wiring between the units don't match up, or there's not enough refrigerant.

    Points to the pipe and cable connections, or low gas

Ducted units with a wired controller

Press Menu on the controller to see the code and the unit number.

  • A3

    The water level in the condensate drain has risen too high.

    Points to the drain pump, the drain pipe or a blockage

  • A8Electrical

    The power feeding the indoor fan board is out of range.

    Points to the indoor fan board or its supply

  • AF

    The drain float has tripped.

    Points to the drain float or the drain line

  • CJElectrical

    The temperature sensor inside the wired controller has failed.

    Points to the wired controller's sensor

  • U5Electrical

    The indoor unit and the wired controller can't talk, for example when two controllers are both set as main.

    Points to the controller wiring or settings, or the indoor board

  • U8Electrical

    The main and second wired controllers can't talk to each other.

    Points to the controller settings or wiring

When a Daikin looks broken but isn't

  • Defrost

    Heating stops for about 4 to 12 minutes with a whistling or running-water sound, and the outdoor unit steams. Warm air comes back once it's done.

  • Stops with the lamp still lit

    That's the unit protecting itself from a big swing in the supply voltage. It restarts by itself in about 3 minutes.

  • Running after you turn it off

    After cooling or dry mode, MOLD PROOF keeps the unit running for up to an hour to dry itself out.

  • Dark display

    The display brightness can be set to off, so the lamps can be dark while the unit's running.

Heat Pump Doctors logo

Heat Pump Doctors, in Manukau since 2012

South Auckland Heat Pump Services is Phil of Heat Pump Doctors. He’s been fixing heat pumps and air con across South Auckland since 2012, and he’s an electrician by trade.

We find the fault first, then tell you what it is and what it’ll take before any repair goes ahead.

More about us

Daikin code questions

Something else? Ring 0800 925 417 or put it in the form.

How do I find the code on my Daikin remote?

Hold Cancel for 5 seconds until 00 blinks, then keep pressing Cancel. Whatever code is showing when the unit gives a long beep is the fault.

My Daikin stopped but the light didn't blink. Is it broken?

If the OPERATION lamp stays lit, the unit has shut down to protect itself from a swing in the supply voltage. It starts again on its own in about 3 minutes.

What does U4 mean on a Daikin?

U4 means the indoor and outdoor units have lost contact, which comes down to the cable between them, a board or the supply. Turn it off at the switchboard and ring Phil with the model.

Send Phil your Daikin code

The brand is already picked. Add the code or the light count, the model and your suburb, and Phil calls you back.

Call 0800 925 417

What helps Phil most

  • The brand and the model number, off the sticker on the side
  • Which light is flashing and how many times, or the code
  • What the unit is doing, and since when
  • A photo of the lights or the sticker