Panasonic heat pump error codes and flashing lights

When the TIMER lamp blinks and the unit stops, a Panasonic has stored an H or F code, and the list below covers what each one means for South Auckland and Manukau homes.

The work
Fault-finding and repairs on heat pumps and air con, plus servicing
Phil
An electrician by trade, fixing heat pumps since 2012
Brands
Mitsubishi, Fujitsu, Panasonic, Daikin and the other main brands
Where
Manukau, Papatoetoe and Māngere down to Papakura, Drury and Beachlands
PANASONICPOWERTIMER
WHAT TO TELL PHILSOUTH AUCKLAND

Panasonic · light flashing · send it to Phil

Brand
Panasonic
Lights
which light, how many flashes
Model
off the side sticker

When your Panasonic shows a fault

If the TIMER lamp is blinking and the unit has stopped, your Panasonic has saved a code, and the remote can show you which one. We fix Panasonic heat pumps all over Manukau and South Auckland, and Phil starts every job from that code.

H codes are mostly sensors, fan motors and the link between the units. F codes are mostly the compressor and the outdoor unit's protection. Most of them come back to an electrical part, which is where Phil's background as an electrician helps.

Once you've got the code, turn the unit off and pass the code and the model on to Phil.

Reading a Panasonic code with the remote

A blinking TIMER lamp with the unit stopped is the fault sign. A blinking POWER lamp isn't, as that's defrost, warm-up or the timer getting ready.

The code is stored in the unit, and the remote reads it with the small CHECK button. It's a recessed hole at the bottom of the remote, so you'll need a pin or the tip of a pen.

Wi-Fi models also show the code in the Comfort Cloud app.

  1. Point the remote at the indoor unit and hold CHECK for 5 seconds, until the remote shows two dashes.
  2. Press the TIMER up or down button. The first code is H00, which means nothing's stored, and each press tries the next code.
  3. When the stored code comes up, the unit beeps for about 4 seconds and the POWER lamp lights. Write that code down.
  4. Hold CHECK for 5 seconds to finish, turn the unit off and send the code to Phil.

The model number

It’s on a sticker on the indoor unit. A photo of it is all Phil needs.

Send it to Phil

The code or the light count, the model and what the unit is doing. Ring 0800 925 417 or use the form below.

Panasonic H and F codes

Not every code turns up on every Panasonic model, so send Phil the model with the code and he'll match it to your unit.

Wall units and floor consoles (CS-Z, CS-RZ, CS-E)

  • F11

    The reversing valve won't switch between heating and cooling.

    Points to the 4-way valve or its wiring

  • F16Electrical

    The unit's total current draw has gone over its limit.

    Points to the compressor, the refrigerant side or the supply

  • F18

    The circuit the unit uses in dry mode is blocked.

    Points to a blockage in the refrigerant circuit

  • F87Electrical

    The outdoor control box is overheating.

    Points to the outdoor control box

  • F90Electrical

    The power factor circuit has tripped its protection, or the outdoor board and the compressor controller have lost contact.

    Points to the outdoor board or the power supply

  • F91

    The refrigerant system isn't working the way it should.

    Points to low gas from a leak, or a valve left closed

  • F93Electrical

    The compressor is running at the wrong speed.

    Points to the compressor or its inverter drive

  • F94

    Pressure leaving the compressor has gone too high.

    Points to the refrigerant system

  • F95

    Pressure has gone too high while cooling.

    Points to airflow at the outdoor unit, the outdoor fan motor or the refrigerant system

  • F96Electrical

    The inverter's power module is overheating.

    Points to the inverter power module or airflow at the outdoor unit

  • F97

    The compressor is overheating, often from a shortage of refrigerant.

    Points to low gas or the compressor

  • F98Electrical

    Running current protection has stepped in and stopped the unit.

    Points to the supply, the compressor or the refrigerant side

  • F99Electrical

    The outdoor board has picked up a sudden spike in current.

    Points to the power module, or a compressor that's locked

  • H00

    No fault stored. It's the first code the remote shows when you step through.

    Points to nothing, it's the starting point

  • H11Electrical

    The indoor and outdoor units have stopped talking to each other.

    Points to the cable between the units or a control board

  • H14Electrical

    The sensor reading the room air has failed.

    Points to the intake air sensor or its plug

  • H15Electrical

    The compressor's temperature sensor has failed.

    Points to the compressor sensor or its plug

  • H16Electrical

    The current sensor on the outdoor board has a fault.

    Points to the current transformer on the outdoor board, or the compressor

  • H17Electrical

    The sensor on the outdoor suction pipe has failed.

    Points to the suction pipe sensor or its plug

  • H19Electrical

    The indoor fan motor has locked up or isn't reporting its speed.

    Points to the indoor fan motor, its plug, or something jammed in the fan

  • H21

    The float switch in the drain has tripped.

    Points to the drain pump, a blocked drain or the float switch

  • H23Electrical

    The first indoor coil sensor has failed.

    Points to indoor coil sensor 1

  • H24Electrical

    The second indoor coil sensor has failed.

    Points to indoor coil sensor 2

  • H25Electrical

    The ion device in the indoor unit has a fault.

    Points to the ion air-purifier board

  • H26Electrical

    The negative ion generator has a fault.

    Points to the ion generator

  • H27Electrical

    The sensor reading the outside air has failed.

    Points to the outdoor air sensor

  • H28Electrical

    The outdoor coil sensor has failed.

    Points to the outdoor coil sensor

  • H30Electrical

    The sensor on the outdoor discharge pipe has failed.

    Points to the discharge pipe sensor

  • H32Electrical

    The second outdoor coil sensor has failed.

    Points to outdoor coil sensor 2

  • H33Electrical

    The indoor and outdoor units are connected, but they're rated for different voltages.

    Points to mismatched units or wiring

  • H34Electrical

    The heat sink sensor on the outdoor board has failed.

    Points to the heat sink sensor on the outdoor board

  • H36Electrical

    The sensor on the outdoor gas pipe has failed.

    Points to the gas pipe sensor

  • H37Electrical

    The sensor on the outdoor liquid pipe has failed.

    Points to the liquid pipe sensor

  • H38

    The indoor and outdoor units aren't a matching brand or type.

    Points to the indoor and outdoor pairing

  • H50Electrical

    The ventilation fan motor has locked up.

    Points to the ventilation fan motor

  • H51Electrical

    A ventilation fan motor or its nozzle has locked up.

    Points to the ventilation fan motor or its nozzle mechanism

  • H52Electrical

    The switch that tells the board where the left-right louvre sits has a fault.

    Points to the louvre limit switch

  • H58Electrical

    The indoor gas sensor has failed.

    Points to the gas sensor

  • H59Electrical

    The ECONAVI sensor has failed or come unplugged.

    Points to the ECONAVI sensor or its board

  • H64Electrical

    The outdoor high-pressure sensor has failed.

    Points to the pressure sensor, its plug or the board

  • H67Electrical

    The nanoe generator has a fault.

    Points to the nanoe generator or its high-voltage supply

  • H70Electrical

    The light sensor has failed or come unplugged.

    Points to the light sensor

  • H71Electrical

    The small cooling fan on the control board has stopped.

    Points to the cooling fan on the control board

  • H79Electrical

    The built-in Wi-Fi module couldn't save its data.

    Points to the Wi-Fi module

  • H85Electrical

    The indoor unit can't talk to its Wi-Fi module.

    Points to the Wi-Fi module or its plug on the indoor board

  • H97Electrical

    The outdoor fan motor has locked up or isn't reporting its speed.

    Points to the outdoor fan motor, its plug, or something blocking the fan

  • H98

    The indoor coil got too hot while heating, and the unit stopped to protect itself.

    Points to a clogged filter, blocked airflow or the indoor coil

    Safe to try a clogged filter can set this off, so give the filters a clean, clear the vents and restart it.

  • H99

    The indoor coil got too cold while cooling and started icing up.

    Points to a clogged filter, blocked airflow or the indoor coil

    Safe to try a dirty unit can cause this one, so give the filters a clean, keep the vents clear and restart it.

Multi-room systems (one outdoor unit, two or more indoor units)

  • F17

    An indoor unit that's switched off is icing up.

    Points to crossed wiring or pipes, a leaking expansion valve, a coil sensor or the outdoor board

  • H12

    The indoor units don't suit the outdoor unit's capacity.

    Points to the wrong combination, or too many or too few indoor units

  • H39Electrical

    An indoor unit is running when it should be idle, or idle when it should be running.

    Points to crossed wiring or pipes between rooms, an expansion valve or a coil sensor

  • H41Electrical

    The wiring or pipes between the rooms are connected the wrong way round.

    Points to crossed wires or pipes, or an expansion valve

Panasonic lights and habits that look like trouble

  • POWER lamp blinking in heat

    During defrost the POWER lamp blinks, the flap closes and no warm air comes out while the outdoor unit can steam. It goes back to heating by itself.

  • Slow start in heat

    At the start of heating the fan holds off until the coil is warm, and the POWER lamp blinks while it warms up.

  • Restart delay

    After it's turned off, or after a power cut, the unit waits around 3 to 4 minutes before it starts again, to protect the compressor.

  • Starting early on a timer

    With an ON timer set, the unit can start up to 35 minutes early, and the POWER lamp blinks beforehand.

Heat Pump Doctors logo

Heat Pump Doctors, in Manukau since 2012

South Auckland Heat Pump Services is Phil of Heat Pump Doctors. He’s been fixing heat pumps and air con across South Auckland since 2012, and he’s an electrician by trade.

We find the fault first, then tell you what it is and what it’ll take before any repair goes ahead.

More about us

Panasonic code questions

Something else? Ring 0800 925 417 or put it in the form.

Is a blinking POWER light on my Panasonic a fault?

No. The POWER lamp blinks during defrost, while it warms up, while AUTO picks a mode and before an ON timer starts. The fault light is the TIMER lamp.

The remote only shows H00. What does that mean?

H00 is the first code in the list and means no fault is stored. Keep pressing the TIMER button until the unit gives the long beep, and the code on the remote then is your fault.

I've got H98 or H99. Is that a breakdown?

Both mean the indoor coil went too hot or too cold, and dirty filters or blocked airflow can be behind it. If it keeps coming back, Phil can find out whether it's airflow, a sensor or the gas.

Send Phil your Panasonic code

The brand is already picked. Add the code or the light count, the model and your suburb, and Phil calls you back.

Call 0800 925 417

What helps Phil most

  • The brand and the model number, off the sticker on the side
  • Which light is flashing and how many times, or the code
  • What the unit is doing, and since when
  • A photo of the lights or the sticker