Mitsubishi Electric heat pump error codes and flashing lights
A blinking lamp on a Mitsubishi Electric is a fault count, and each count points to a part. Here's what they mean for homes in Manukau and South Auckland.
- The work
- Fault-finding and repairs on heat pumps and air con, plus servicing
- Phil
- An electrician by trade, fixing heat pumps since 2012
- Brands
- Mitsubishi, Fujitsu, Panasonic, Daikin and the other main brands
- Where
- Manukau, Papatoetoe and Māngere down to Papakura, Drury and Beachlands
Mitsubishi · light flashing · send it to Phil
- Brand
- Mitsubishi Electric
- Lights
- which light, how many flashes
- Model
- off the side sticker
When your Mitsubishi shows a fault
Mitsubishi Electric wall units don't show letters when something goes wrong. The indoor fan stops and one lamp on the right of the unit blinks a count, pauses, then starts again. We look after these units across Manukau and South Auckland, and that count is the first thing Phil wants to know.
Nearly every count points to something electrical, like a sensor, a fan motor, a board or the outdoor unit's power side. Phil's an electrician by trade, so that's home ground for him.
Send Phil the count and the model off the label. If the unit keeps tripping the power, turn it off at the isolator or the switchboard and leave it off.
Counting the blinks on a Mitsubishi Electric
Each blink is quick, about half a second, and there's a gap of two and a half seconds before the count repeats. Count the blinks between gaps and watch it go round twice to be sure.
Which lamp carries the count depends on the model. On the MSZ-AP it's the upper of the two lamps, on the MSZ-EF it's the left lamp, and on the MSZ-LN it's the POWER lamp. The counts mean the same on all three.
Ducted and Mr Slim units with a controller on the wall show a letter and a number instead, like P8 or U4. Those have their own group further down.
The model number
The model number is on the label on the indoor unit, and the remote's model is printed on its back.
Send it to Phil
The code or the light count, the model and what the unit is doing. Ring 0800 925 417 or use the form below.
Mitsubishi Electric blink counts and codes
Find your blink count, or the code on your wall controller, to see what it points to.
Wall units (MSZ-AP, MSZ-EF, MSZ-LN, MSZ-GE)
Count the blinks on the fault lamp between the gaps.
Blinking with no gapElectrical
The lamp flashes on and off without ever pausing. The indoor unit hasn't heard from the outdoor unit for about 6 minutes.
Points to the cable between the units, the outdoor unit's power or a control board
2 blinksElectrical
A temperature sensor inside the indoor unit has failed or its circuit is broken. It's either the one reading the room or the one on the coil.
Points to the room or indoor coil sensor, or its plug on the board
3 blinksElectrical
The indoor fan should be turning, but the board isn't getting any speed signal back from it.
Points to the indoor fan motor, its wiring or the indoor board
4 blinksElectrical
The indoor control board can't read its own memory.
Points to the indoor control board
5 blinksElectrical
The outdoor unit has shut down on a power fault. The compressor pulled too much current or failed to start three times inside a minute, so both units stop.
Points to the inverter board, the compressor or its plug, or a closed valve
6 blinksElectrical
One of the outdoor unit's temperature sensors has failed while the compressor was running.
Points to an outdoor sensor (discharge, defrost, fin, outside air or coil)
7 blinksElectrical
The outdoor control board can't read its memory.
Points to the inverter board or the outdoor control board
14 or more blinks
Something else has gone wrong in the outdoor unit. Phil reads the detail from the outdoor unit itself.
Points to a valve, the reversing valve or another outdoor fault
Steady lamp, outdoor unit stoppedElectrical
On an MSZ-AP the upper lamp stays lit but the outdoor unit won't run. The outdoor board can't read its memory.
Points to the inverter board or the outdoor control board
Ducted and Mr Slim units with a wired controller (SEZ, PEAD)
The code shows on the controller screen. Newer controllers can show a 4-digit number, listed with the code.
E0 / E3Electrical
The wired controller and the indoor unit aren't getting messages through to each other.
Points to the controller wiring or the controller
E1 / E2Electrical
The wired controller's own board has a fault. On E1 that can be its clock.
Points to the wired controller
E4 / E5Electrical
The indoor unit isn't picking up the controller's signal properly.
Points to the controller wiring, the controller or the indoor board
E6 / E7Electrical
The indoor unit has lost contact with the outdoor unit.
Points to the cable between the units, a control board or electrical noise on the line
E8Electrical
The outdoor unit isn't receiving anything from the indoor unit.
Points to the cable between the units or a control board
E9Electrical
The outdoor unit is sending to the indoor unit, and the messages aren't getting through.
Points to the cable between the units or the outdoor board
EA / Eb / ECElectrical
At switch-on, the outdoor unit found the wiring between the units isn't right, or its start-up check ran out of time.
Points to the cable between the indoor and outdoor units
EE
The indoor and outdoor units don't belong together. They can be built for different refrigerants.
Points to the indoor and outdoor pairing
EFElectrical
The indoor unit has received a code it doesn't recognise, often from electrical noise on the cable between the units.
Points to noise on the connecting cable, or the controller
F5Electrical
The high-pressure switch circuit in the outdoor unit has read open for 3 minutes after switch-on.
Points to the high-pressure switch, its wiring or the outdoor board
FbElectrical
The indoor control board has a fault, such as a memory error.
Points to the indoor control board
P1Electrical
The sensor reading the air coming into the unit has failed.
Points to the intake air sensor (TH1)
P2Electrical
The sensor on the indoor pipe has failed.
Points to the indoor pipe sensor (TH2)
P4Electrical
The drain sensor has failed, or the float switch plug has come open.
Points to the drain sensor or the float switch wiring
P5
The drain pump isn't getting the water away.
Points to the drain pump or a blocked drain
P6
The indoor coil got too cold or too hot, and the protection stepped in.
Points to airflow over the coil (filters or the fan), or the refrigerant
P8
After the compressor starts, the indoor coil isn't changing temperature the way it should.
Points to a valve not fully open, the indoor fan not turning, a sensor or a refrigerant problem
P9Electrical
The second sensor on the indoor pipe has failed.
Points to the indoor pipe sensor (TH5)
PA
The compressor has been forced off because of a water problem in the drain.
Points to the drain pump, the drain tray or the drain sensor
PbElectrical
The indoor fan motor has a fault.
Points to the indoor fan motor or the indoor board
PL
Something's wrong in the refrigerant circuit, like a closed valve, air in the pipes or the coil running far too hot.
Points to low gas or air in the system, a valve, or the indoor fan not running
U1
Pressure in the system went too high and the high-pressure switch cut in.
Points to the refrigerant circuit, the outdoor fan, blocked airflow or a closed valve
U2
The compressor or the pipe leaving it is running too hot, which often comes down to a shortage of refrigerant.
Points to low gas, the expansion valve or a sensor
U3Electrical
The sensor on the compressor or its discharge pipe has failed.
Points to the outdoor discharge or compressor sensor
U4Electrical
One of the other outdoor temperature sensors has failed.
Points to an outdoor temperature sensor
U5
The heat sink on the outdoor board has got too hot.
Points to a stuck outdoor fan motor, blocked airflow or heat building up around the outdoor unit
U6Electrical
The power module on the outdoor board has tripped on overcurrent.
Points to the power module, the outdoor inverter board or the compressor
U7
The pipe leaving the compressor is running too cool, so the system has too little superheat.
Points to the expansion valve, a sensor or the gas charge
U8Electrical
The outdoor fan motor has stopped on its protection.
Points to the outdoor fan motor or its drive circuit on the board
U9Electrical
The power coming in is out of range, too high, too low or distorted.
Points to the mains supply or the outdoor board
Ud
The outdoor unit has shut down on overheat protection.
Points to the refrigerant circuit, airflow or the outdoor board
UFElectrical
The compressor pulled too much current because it's locked and can't turn.
Points to the compressor or the outdoor board
UHElectrical
The current sensor isn't giving a proper reading.
Points to a loose compressor wire or the outdoor board
UL
Pressure on the low side of the system has dropped too far.
Points to a gas leak, the expansion valve or a blockage
UPElectrical
The compressor cut out on overcurrent.
Points to a closed valve, low supply voltage, the compressor or its wiring, or the outdoor board
Mitsubishi Electric or Mitsubishi Heavy Industries?
They're two separate makers, and their heat pumps don't share lights or codes. Everything on this page is for Mitsubishi Electric.
Have a look at the model on the label. Mitsubishi Electric models start with MSZ, MUZ, MFZ, MXZ, SEZ, SUZ, PEAD or PUZ. A wall unit starting with SRK is Mitsubishi Heavy Industries.
If yours is a Mitsubishi Heavy, count the flashes on each light on the front and send Phil those counts with the model. He'll match them to that unit.
Things a Mitsubishi Electric does that aren't faults
Defrost
In heating, the warm air can stop for up to 10 minutes while the outdoor unit steams and drips. The fan slows or stops, then heating starts again by itself.
The 3-minute wait
Once it's been turned off, the unit won't start again for about 3 minutes. That protects the compressor.
Two lamps on a multi-room system
Upper lamp on and lower lamp blinking means one room is set to heat while another is on cool. The room that started first wins, and setting every room to the same mode gets the other going.
Dim lamp at night
Night mode dims the lamp and turns off the beeps, so the unit can look dead when it's running fine.

Heat Pump Doctors, in Manukau since 2012
South Auckland Heat Pump Services is Phil of Heat Pump Doctors. He’s been fixing heat pumps and air con across South Auckland since 2012, and he’s an electrician by trade.
We find the fault first, then tell you what it is and what it’ll take before any repair goes ahead.
Other brands’ codes
- FujitsuOperation and Timer flashes that make a two-digit code
- PanasonicH and F codes behind a blinking timer light
- DaikinU, A, E, F and L codes, read with the remote
- HitachiTimer lamp blink counts
- ToshibaWhich lamps flash together, and how fast
- LGCH codes on the display or as lamp blinks
- SamsungE and C codes on the indoor display
- HaierE and F codes on the two-digit display
- GreeE, F, H and L codes on the temperature display
- CarrierE, P and F codes in the display window
Mitsubishi code questions
Something else? Ring 0800 925 417 or put it in the form.
My Mitsubishi blinked 5 times and both units stopped. What's that?
Five blinks is the outdoor unit shutting down on a power fault around the compressor or its inverter board. Turn it off at the isolator and send Phil the count and the model.
Can I bring up the last fault on a Mitsubishi Electric wall unit myself?
No. These wall units have no owner check button. The stored fault is read on the day, so just tell us what the lamp was doing.
Is a blinking lower lamp a fault?
Not on its own. On a multi-room system, the upper lamp on with the lower lamp blinking means two rooms want heating and cooling at once. Set them to the same mode and it sorts itself out.
Send Phil your Mitsubishi code
The brand is already picked. Add the code or the light count, the model and your suburb, and Phil calls you back.
What helps Phil most
- The brand and the model number, off the sticker on the side
- Which light is flashing and how many times, or the code
- What the unit is doing, and since when
- A photo of the lights or the sticker