Haier heat pump error codes and flashing lights

Your Haier has stopped and there's a code on the front, or a lamp blinking on the ducted receiver. Find it below to see what it points to, for Haier owners in Manukau and South Auckland.

The work
Fault-finding and repairs on heat pumps and air con, plus servicing
Phil
An electrician by trade, fixing heat pumps since 2012
Brands
Mitsubishi, Fujitsu, Panasonic, Daikin and the other main brands
Where
Manukau, Papatoetoe and Māngere down to Papakura, Drury and Beachlands
HAIERF1POWER
WHAT TO TELL PHILSOUTH AUCKLAND

Haier · code F1 · send it to Phil

Brand
Haier
Code
F1
Model
off the side sticker

When your Haier shows a fault

Haier heat pumps around Manukau and South Auckland stop and show a code when something's wrong. Wall units put it on the front display where the temperature sits, and ducted and cassette units flash a lamp on the receiver.

Phil starts from that code. Most Haier codes point to a sensor, a board, a fan motor or the power supply, and Phil's an electrician by trade, so that's his side of things.

Note the code, or count the flashes, and send it to Phil with the model number off the unit.

How a Haier shows its fault

On a Haier wall unit, the code comes up on the two-digit display in place of the temperature. E codes are mostly the indoor side and F codes the outdoor side.

Ducted and cassette units stop the indoor fan and flash the Running lamp on the receiver, so count the flashes between pauses. For an outdoor fault, the Timer lamp flashes the tens first, then the Running lamp flashes the units, with a 4-second gap before it repeats.

With a YR-E17A wall controller, a warning triangle comes up on the screen and you can bring the code up yourself.

  1. With the controller's backlight on, hold TIME for 10 seconds.
  2. The code shows top left. The number left of the colon is the fault now, and the one on the right is the last one stored.
  3. Press TIME (don't hold it) to step back through older faults. Two dashes means nothing's stored.

The model number

It’s on a sticker on the indoor unit. A photo of it is all Phil needs.

Send it to Phil

The code or the light count, the model and what the unit is doing. Ring 0800 925 417 or use the form below.

What each Haier code points to

Find your code in the group that matches your unit, because E9, F3 and F8 mean different things on a wall unit and on a ducted or cassette unit.

Wall units, E codes (indoor side)

Shows on the two-digit display on the front of the indoor unit.

  • E1Electrical

    The sensor that reads the room's air temperature is giving a reading that can't be right, so the unit has stopped.

    Points to the room temperature sensor, its plug or the indoor board

  • E2Electrical

    The sensor on the indoor coil has dropped out or shorted.

    Points to the indoor coil sensor, its plug or the indoor board

  • E4Electrical

    The indoor board can't read its memory chip, or the settings stored on it have gone bad.

    Points to the indoor circuit board

  • E5

    The indoor coil has got too cold, and the unit has shut down before it ices over.

    Points to airflow through the indoor unit, the indoor fan, the coil sensor or a low gas charge

  • E7Electrical

    The indoor and outdoor units have lost contact with each other.

    Points to the cable between the units, its terminals, or a board at either end

  • E9

    On a wall unit, the indoor side has run too hot in heating and the unit has backed off to protect itself.

    Points to the gas charge, the coil sensor, the indoor board or a blocked filter

  • E14Electrical

    The indoor fan isn't turning, or the board can't tell how fast it's going.

    Points to the indoor fan motor or the indoor board

Wall units, F codes (outdoor side)

These show on the indoor display too, even though the fault is in the outdoor unit.

  • F1Electrical

    The inverter power module in the outdoor unit has shut itself down on a fault.

    Points to the outdoor power module

  • F2Electrical

    The compressor pulled a sudden surge of current and the outdoor unit cut out.

    Points to the power module, the power supply, the compressor or the gas charge

  • F3Electrical

    On a wall unit, the outdoor control board has lost contact with the power module beside it.

    Points to the plugs and loom between the outdoor board and the power module

  • F4

    The pipe leaving the compressor is running too hot, so the unit has stopped to save the compressor.

    Points to a gas leak or low charge, a blocked coil, or the discharge sensor

  • F6Electrical

    The outdoor air temperature sensor has failed open or shorted.

    Points to the outdoor air sensor or the outdoor board

  • F7Electrical

    The sensor on the outdoor unit's suction pipe is giving a bad reading.

    Points to the suction pipe sensor or the outdoor board

  • F8Electrical

    On a wall unit, the outdoor fan motor isn't running the way it should.

    Points to the outdoor fan motor or the outdoor board

  • F9Electrical

    The inverter module has restarted itself when it shouldn't have.

    Points to the inverter module or the power feeding it

  • F11Electrical

    The compressor has fallen out of step with the inverter that drives it.

    Points to the power module, the compressor or its wiring

  • F12Electrical

    The memory chip on the outdoor board has a fault.

    Points to the outdoor circuit board

  • F13

    The unit has worked out that it's short of refrigerant.

    Points to a gas leak or low charge

  • F14

    The valve that swaps the unit between heating and cooling hasn't changed over.

    Points to the reversing valve or its coil

  • F19Electrical

    The power coming in is too high or too low for the unit to run on.

    Points to the mains supply or the outdoor power module

  • F20

    Pressure in the refrigerant circuit went too high and the unit stopped.

    Points to airflow over the coils, the gas charge or a blockage

  • F21Electrical

    The outdoor coil sensor that times the defrost is reading open or short.

    Points to the outdoor coil sensor or the outdoor board

  • F22Electrical

    The outdoor unit drew too much current from the mains.

    Points to the power module, the supply or the gas charge

  • F23Electrical

    One of the compressor's three windings is pulling too much current.

    Points to the power module, the compressor or the supply

  • F24Electrical

    The circuit that measures current in the outdoor unit is reading wrong.

    Points to the current sensor on the outdoor board

  • F25Electrical

    The temperature sensor on the compressor's outlet pipe has dropped out or shorted.

    Points to the discharge sensor or the outdoor board

  • F27Electrical

    The compressor has stalled, or the circuit that measures its current has a fault.

    Points to the compressor or its drive circuit

  • F28Electrical

    The drive can't tell where the compressor's rotor is, so it can't run it.

    Points to the power module or the compressor

  • F35Electrical

    The board that drives the compressor has failed.

    Points to the compressor driver board

  • F36Electrical

    The sensor halfway along the outdoor coil is giving a bad reading.

    Points to the mid-coil sensor or the outdoor board

  • F43

    The indoor and outdoor units don't match each other, or a board has been set up wrong.

    Points to the pairing of the two units or a board setting

  • FE

    On a fixed-speed unit, the leak check has picked up a refrigerant problem.

    Points to a gas leak or low charge

Ducted and cassette units, indoor faults

Each one shows as a code on the display panel, a number on the wall controller, or a count of Running lamp flashes.

  • E0 / 0C / 12 flashes

    Water isn't draining away from the indoor unit, or the float switch has tripped.

    Points to the drain pump or the float switch

  • E1 / 01 / 1 flashElectrical

    The return-air sensor that reads the room temperature has failed, come loose or shorted.

    Points to the return-air sensor or its plug

  • E2 / 02 / 2 flashesElectrical

    The sensor on the indoor coil has failed, come loose or shorted.

    Points to the indoor coil sensor or its plug

  • E8 / 8 flashesElectrical

    The wall controller and the indoor board have stopped talking. The wall controller can't show this one itself.

    Points to the controller cable, the controller or the indoor board

  • E9 / 07 / 7 flashesElectrical

    On a ducted or cassette unit, the indoor and outdoor units can't talk to each other.

    Points to the wiring between the units, the address setting, the supply or a board

  • EF / 0D / 13 flashesElectrical

    The indoor board isn't picking up a clean timing signal from the mains.

    Points to the indoor board, or a short in the wall controller

  • F3 / 10 / 16 flashes

    On a ducted or cassette unit, the indoor unit is asking for a different mode from the outdoor unit.

    Points to a mode clash between indoor and outdoor, mostly on systems with more than one indoor unit

  • F8 / 04 / 4 flashesElectrical

    On a ducted or cassette unit, the memory chip on the indoor board has a fault.

    Points to the indoor circuit board

  • 0E / 14 flashesElectrical

    The indoor fan motor isn't working right. There's no letter code on the panel for this one.

    Points to the indoor fan motor, its plug or its circuit

Ducted and cassette units, outdoor faults

The Timer lamp flashes the tens, then the Running lamp flashes the units, so 2 then 3 is 23. The wall controller shows these as a different number, and a few differ on some outdoor sizes, so send Phil the outdoor model too.

  • 21Electrical

    The memory chip on the outdoor board has a fault.

    Points to the outdoor main board

  • 22Electrical

    The outdoor power module has cut out on a current spike.

    Points to the power module or the compressor drive

  • 23Electrical

    The outdoor unit has seen too much current, either from the mains or while the compressor was slowing down.

    Points to the compressor drive or the supply

  • 24Electrical

    The outdoor control board and the compressor drive have lost contact for more than 4 minutes.

    Points to the driver module, the outdoor main board or the loom between them

  • 25Electrical

    The outdoor board has picked up too much current on the compressor.

    Points to the compressor, its drive or the supply

  • 26Electrical

    The supply voltage, or the voltage inside the outdoor drive, is too high. It clears itself once it's back to normal.

    Points to the mains supply or the outdoor power circuit

  • 27Electrical

    The circuit in the drive module that measures compressor current has failed.

    Points to the driver module

  • 28

    The compressor's outlet pipe has got too hot. It resets as it cools, but locks out after three trips in an hour.

    Points to low gas, a blockage or poor airflow

  • 29Electrical

    The outdoor fan motor has failed, jammed or come unplugged. Three trips in half an hour locks the unit out.

    Points to the outdoor fan motor, its plug or its circuit

  • 30Electrical

    The outdoor coil sensor is out of range, open or shorted.

    Points to the outdoor coil sensor

  • 31Electrical

    The sensor on the suction pipe is giving a reading out of range.

    Points to the suction pipe sensor

  • 32Electrical

    The outdoor air sensor is giving a reading out of range.

    Points to the outdoor air sensor

  • 33Electrical

    The sensor on the compressor's outlet pipe is open, shorted or out of range.

    Points to the discharge sensor

  • 34Electrical

    The voltage in the power-factor circuit has gone too high.

    Points to the PFC circuit on the outdoor board, or the supply

  • 35Electrical

    The indoor and outdoor units haven't talked to each other for more than 4 minutes.

    Points to the cable between the units, or a board at either end

  • 36

    The system is low on refrigerant, or the pipe out of the compressor is blocked. Three trips in an hour locks it out.

    Points to a gas leak or a blockage

  • 37

    The valve that switches between heating and cooling hasn't changed over. Three trips in an hour locks it out.

    Points to the reversing valve or its coil

  • 38Electrical

    The compressor has lost step with its drive, or jammed.

    Points to the compressor, its drive or the current sensing

  • 39Electrical

    The supply voltage, or the voltage inside the outdoor drive, has dropped too low.

    Points to the mains supply or the outdoor drive circuit

  • 40

    The indoor coil has got too hot in heating. It resets once it cools down.

    Points to poor airflow through the indoor unit, a blocked filter or too much gas

Haier behaviour that isn't a fault

  • Heat stops for a few minutes

    Roughly once an hour in cold weather the outdoor unit defrosts for 5 to 12 minutes. Heating pauses, and you might see steam or water coming off the outdoor unit.

  • Fan won't start in heating

    The indoor fan stays off for a couple of minutes until the coil's warm, so it doesn't blow cold air at you.

  • Won't restart straight away

    After it's been switched off, or the power's been off, the compressor waits 3 minutes before it starts again.

  • CL, LL or HH on the display

    CL means Self Clean is running. On the wall controller, LL or HH flashing is a forced cooling or heating test, and OUt or d1 to d3 are quiet and demand modes.

Heat Pump Doctors logo

Heat Pump Doctors, in Manukau since 2012

South Auckland Heat Pump Services is Phil of Heat Pump Doctors. He’s been fixing heat pumps and air con across South Auckland since 2012, and he’s an electrician by trade.

We find the fault first, then tell you what it is and what it’ll take before any repair goes ahead.

More about us

Haier code questions

Something else? Ring 0800 925 417 or put it in the form.

Why does E9 mean something different on my ducted Haier?

Haier uses some of the same codes for different faults on wall units and on ducted or cassette units. E9, F3 and F8 are the ones that catch people out, so tell Phil which kind you've got when you send the code.

How do I count the flashes on a ducted Haier?

Count the Running lamp flashes between pauses. If the Timer lamp flashes first, that's the tens and the Running lamp gives the units, so 2 then 3 is 23.

Why won't my Haier come back on straight after I switch it off?

It waits 3 minutes before the compressor starts again, and does the same after a power cut. If it still won't run after that, turn it off at the isolator and send Phil whatever's on the display.

Send Phil your Haier code

The brand is already picked. Add the code or the light count, the model and your suburb, and Phil calls you back.

Call 0800 925 417

What helps Phil most

  • The brand and the model number, off the sticker on the side
  • Which light is flashing and how many times, or the code
  • What the unit is doing, and since when
  • A photo of the lights or the sticker