Gree heat pump error codes and flashing lights
When your Gree's temperature display turns into a flashing code like E6, F0 or H6, the list below says what it points to. It's written for Gree owners in Manukau and South Auckland.
- The work
- Fault-finding and repairs on heat pumps and air con, plus servicing
- Phil
- An electrician by trade, fixing heat pumps since 2012
- Brands
- Mitsubishi, Fujitsu, Panasonic, Daikin and the other main brands
- Where
- Manukau, Papatoetoe and Māngere down to Papakura, Drury and Beachlands
Gree · code H6 · send it to Phil
- Brand
- Gree
- Code
- H6
- Model
- off the side sticker
When your Gree shows a fault
When a Gree wall unit in Manukau or South Auckland hits a fault, it stops or slows itself down and flashes a short code on the front display. Weka, Kingfisher and Kea AI models all show their codes that way.
Some Gree codes just mean the unit has turned the compressor down and is still running. Others, like E6 or H6, stop it altogether. A lot of them point to sensors, boards and the power supply, which suits Phil, who's an electrician by trade.
Take a photo of the code while it's flashing and send it through to Phil with the model.
Where the Gree code shows up
A Gree wall unit flashes the code on its two-digit display, the same spot that shows the temperature. On a ducted Gree, the code comes up on the wall controller.
There's no way to bring an old code back up with the remote, so grab it while it's showing.
The model number
It’s on a sticker on the indoor unit. A photo of it is all Phil needs.
Send it to Phil
The code or the light count, the model and what the unit is doing. Ring 0800 925 417 or use the form below.
Gree codes, wall units and ducted
Wall unit codes come first, then the ones a ducted Gree shows on its wall controller.
Wall units (Weka, Kingfisher, Kea AI and others)
Flashes on the two-digit display on the front of the indoor unit.
C5Electrical
The small capacity plug on the indoor board is missing or faulty, so the unit takes your commands but won't act on them.
Points to the jumper cap on the board, or the board itself
E1
Refrigerant pressure has gone too high, and the unit has stopped to protect itself.
Points to airflow around the coils, a dirty coil, too much gas, or a very hot day
Safe to try switch it off and on again. If E1 comes back, it needs Phil.
E3
Pressure on the low side has dropped, which points to lost gas or a blockage.
Points to a gas leak, a blockage or the low-pressure switch
E4
The pipe out of the compressor is running too hot, so the unit has stopped.
Points to low gas, the expansion valve, or the unit working too hard
E5Electrical
The unit pulled more current than it should and shut down.
Points to the power supply under load, or a dirty indoor coil
Safe to try switch it off and on again. If E5 comes back, it needs Phil.
E6Electrical
The indoor and outdoor units have lost touch with each other.
Points to the cable between the units, its terminals, or a main board at either end
Safe to try switch it off and on again. If E6 comes back, it needs Phil.
E8
The system is running too hot and has protected itself.
Points to blocked airflow, the outdoor fan or its capacitor, or the main board
Safe to try switch it off and on again. If E8 comes back, it needs Phil.
EEElectrical
The memory chip on the outdoor board has failed.
Points to the outdoor control board
EUElectrical
The inverter module is warm, so the unit has turned the compressor down. It keeps running.
Points to cooling on the power module, or the outdoor board
F0
Either the unit's been put into a pump-down service mode, or it's picked up a refrigerant problem like a leak or a blockage. Both need Phil to have a look.
Points to the refrigerant circuit, or a service mode left on
F1Electrical
The room temperature sensor in the indoor unit has failed open or shorted.
Points to the room sensor, its plug or the main board
F2Electrical
The sensor on the indoor coil has failed open or shorted.
Points to the indoor coil sensor, its plug or the main board
F3Electrical
The outdoor air temperature sensor has failed open or shorted.
Points to the outdoor air sensor or its connection
F4Electrical
The sensor on the outdoor coil has failed open or shorted.
Points to the outdoor coil sensor or its connection
F5Electrical
The sensor on the compressor's outlet pipe has failed, and the unit stops a few minutes later.
Points to the discharge sensor, or the sensor sitting loose in its pocket
F6
The compressor's been turned down because the unit is overloaded. It keeps running.
Points to the unit working too hard, or high temperatures
F8Electrical
The compressor's been turned down because current is running high. It keeps running.
Points to low supply voltage, high pressure or overload
F9
The compressor's been turned down because its outlet pipe is hot. It keeps running.
Points to overload, low gas or the expansion valve
FH
The compressor's been turned down so the indoor coil doesn't ice up. It keeps running.
Points to poor return air to the indoor unit, or a low fan speed
H3
The overload switch on the compressor has tripped because the compressor's too hot.
Points to a loose overload connection, low gas, or the unit working too hard
Safe to try switch it off and on again. If H3 comes back, it needs Phil.
H4
The unit has picked up a general overload and protected itself.
Points to the unit running too hot or working too hard
H5Electrical
The inverter power module has tripped on a fault.
Points to the power module, the outdoor board, the compressor or the supply
H6Electrical
The indoor fan isn't turning, or the board can't read its speed.
Points to the indoor fan motor, its plug or the main board
Safe to try switch it off and on again. If H6 comes back, it needs Phil.
H7Electrical
The compressor has fallen out of step with the inverter drive.
Points to the compressor, its wiring or the outdoor board
HCElectrical
The power-factor circuit in the outdoor unit has tripped.
Points to the PFC circuit on the outdoor board, or the supply
JFElectrical
The Wi-Fi board has a fault, so the app can't run the unit.
Points to the Wi-Fi module
L3Electrical
The outdoor fan motor isn't running, so the compressor has stopped.
Points to the outdoor fan motor, a loose plug, or a blockage
L9Electrical
The unit is drawing too much power. The compressor and outdoor fan stop, then try again after 3 minutes.
Points to overload or the supply
LCElectrical
The compressor didn't start.
Points to the compressor, its wiring or the outdoor board
LP
The indoor and outdoor units aren't a matching pair, so the compressor won't run.
Points to mismatched units or a board setting
oEElectrical
The outdoor unit has a fault the indoor unit can't put a name to.
Points to outdoor conditions out of range, the compressor or its wiring, or the outdoor board
P5Electrical
The compressor drew too much current on one of its phases.
Points to the compressor, the power module or the supply
P7Electrical
The temperature sensor circuit on the inverter module has failed.
Points to the outdoor control board
P8Electrical
The inverter module is overheating.
Points to cooling on the power module, or the outdoor board
PHElectrical
The DC voltage inside the outdoor unit is too high.
Points to high mains voltage, a capacitor or the outdoor board
PLElectrical
The DC voltage inside the outdoor unit is too low.
Points to low mains voltage, a capacitor or the outdoor board
PUElectrical
The capacitor in the inverter isn't charging the way it should.
Points to the charging circuit on the outdoor board
U1Electrical
The circuit that measures the compressor's current has failed.
Points to the outdoor control board
U3Electrical
The DC voltage in the outdoor unit keeps dropping out.
Points to an unsteady mains supply
U5Electrical
The circuit that measures the whole unit's current has failed.
Points to the outdoor control board
U7
The valve that swaps between heating and cooling isn't working, so the unit stops in heating.
Points to low supply voltage, a loose valve coil connection, or the reversing valve
U8Electrical
The indoor board has lost the timing signal it takes from the mains, and the whole unit stops.
Points to the power supply or the indoor main board
Safe to try switch it off and on again. If U8 comes back, it needs Phil.
U9Electrical
The outdoor board has lost the timing signal it takes from the mains.
Points to the supply or the outdoor board
Humidity 0%Electrical
On a Kea AI, a humidity reading stuck at 0% can mean the humidity sensor board has failed.
Points to the humidity board
Ducted units with a wall controller
These show on the wall controller.
E7
Indoor units on the same outdoor unit are asking for opposite modes, one heating and one cooling.
Points to the mode settings across the rooms
EA
The refrigerant leak sensor has picked up a leak.
Points to a refrigerant leak
FCElectrical
A small safety switch in the unit has a fault.
Points to the micro switch
FEElectrical
The refrigerant leak sensor has worn out or been damaged.
Points to the leak sensor
HEElectrical
The compressor motor has lost its magnetism and the drive has shut it down.
Points to the compressor
LdElectrical
The unit has lost one phase of its power supply.
Points to the supply to the unit
P6Electrical
The drive board and the outdoor main board have stopped talking.
Points to the drive board, the main board or the loom between them
U2Electrical
The compressor has lost one of its phases.
Points to the compressor wiring
Gree codes and lights that aren't faults
Heating lamp blinking
When the outdoor unit defrosts in heating, the heating lamp goes off for a moment and then blinks, and the indoor fan stops. Older Gree units show H1 instead. Heat comes back once it's done.
E2 or E9 on the display
E9 means the fan is holding off at the start of heating until the coil's warm. E2 means the unit is stopping the indoor coil from icing up. Neither is a fault on its own, and both clear themselves.
Fo on the display
Fo, with a small o, is a refrigerant recovery mode a technician uses before working on the pipes. Any button on the remote takes it out. If Fo shows up and nobody's been working on the unit, send Phil the code.
CL, or the display flashing at start-up
CL means the unit's own auto clean is running. On a Kea AI, the temperature display flashing for about 30 seconds when it starts is the filter reminder.

Heat Pump Doctors, in Manukau since 2012
South Auckland Heat Pump Services is Phil of Heat Pump Doctors. He’s been fixing heat pumps and air con across South Auckland since 2012, and he’s an electrician by trade.
We find the fault first, then tell you what it is and what it’ll take before any repair goes ahead.
Other brands’ codes
- Mitsubishi ElectricBlink counts on the operation lamp, and P, E and U codes
- FujitsuOperation and Timer flashes that make a two-digit code
- PanasonicH and F codes behind a blinking timer light
- DaikinU, A, E, F and L codes, read with the remote
- HitachiTimer lamp blink counts
- ToshibaWhich lamps flash together, and how fast
- LGCH codes on the display or as lamp blinks
- SamsungE and C codes on the indoor display
- HaierE and F codes on the two-digit display
- CarrierE, P and F codes in the display window
Gree code questions
Something else? Ring 0800 925 417 or put it in the form.
What does F0 mean on a Gree?
F0 points to the refrigerant side. Either the unit has been left in a pump-down service mode, or it's picked up a leak or a blockage, so turn it off and send Phil the code and model.
Is Fo the same as F0?
No. Fo with a small o is a recovery mode a technician puts the unit into, and any press on the remote takes it out. F0 with a zero is the refrigerant code in the list.
My Gree shows F8 but it's still running. Is it broken?
F6, F8, F9, FH and EU mean the unit has turned the compressor down to protect itself and kept going. If one keeps showing, or the room isn't getting warm, flick the code to Phil.
Send Phil your Gree code
The brand is already picked. Add the code or the light count, the model and your suburb, and Phil calls you back.
What helps Phil most
- The brand and the model number, off the sticker on the side
- Which light is flashing and how many times, or the code
- What the unit is doing, and since when
- A photo of the lights or the sticker